Basic Introduction to Busbars


Release Time:

Nov 13,2019

Busbar trunking, refers to an enclosed metal device made of copper and aluminum busbars, used to distribute large power to various components of a dispersed system. The features of busbar trunking include series matching, commercial production, small size, large capacity, short design and construction cycle, easy installation and removal, non-combustibility, safety and reliability, and long service life. Busbar trunking products are suitable for three-phase four-wire and three-phase five-wire power distribution systems with AC 50Hz, rated voltage 380V, and rated current 250A-4000A. Insulation support is a component of the busbar trunking equipment, used to support the conductors in the busbar trunking equipment. Mounting plates are used to support various components and are suitable for mounting in complete sets of equipment. Mounting frames are used to support various components and are suitable for mounting in complete sets of equipment. Enclosure: The enclosure protects the equipment from certain external factors and prevents direct access to the equipment in all directions. Its protection level is at least IP30. Door: A hinged or sliding cover plate. Cover plate: The upper and lower shell surfaces of the enclosure, usually a component on the busbar trunking equipment, is used to cover the openings on the enclosure. It is fixed with screws or similar methods, and generally not removed after the equipment is put into operation. Side plate: The left and right shell surfaces of the enclosure, usually a component on the busbar trunking equipment, is used to cover the openings on the enclosure. It is fixed with screws or similar methods, and generally not removed after the equipment is put into operation. Insulation partition: A component used to protect against direct contact from all directions at the entrance and from arcs from switching devices and similar devices. Live part: Conductors or conductive parts energized during normal use, including the neutral conductor, but not including the neutral protective conductor. Exposed conductive part: An accessible conductive part of an electrical equipment, usually not energized but may be energized in case of fault. Protective conductor: A conductor electrically connected to the following parts to prevent electric shock hazards. Special note: Cables are indicated by cross-sectional area, and busbar trunking is indicated by rated operating current (generally referred to as 400A busbar trunking). Similarly, domestic products with 400A have a cross-sectional area of 240mm, while some are only 180mm. Guangzhou Tianqin Electrical Equipment Co., Ltd. is located beside Shapu Lixin Highway, Xintang Town, Zengcheng District, Guangzhou City (opposite Zengcheng Guangben Factory). The company focuses on the R&D, production, sales, and installation of busbar trunking products, providing comprehensive services for busbar trunking power distribution systems, and providing busbar trunking power distribution system products and engineering services for numerous enterprises. Welcome to consult: 13926168592.

Busbar trunkingIt refers to a closed metal device composed of copper and aluminum busbars, used to distribute large power to various components of a distributed system.

Busbar trunking features include a series of supporting components, commercial production, small size, large capacity, short design and construction cycle, easy installation and removal, non-combustible, safe and reliable, and long service life. Busbar trunking products are suitable for AC 50Hz, rated voltage 380V, rated current 250A-4000A three-phase four-wire and three-phase five-wire power distribution systems.

Busbar trunking

 

Insulating supports are components of busbar trunking equipment, used to support the conductors in the busbar trunking equipment.

Mounting plates are used to support various components and are suitable for installation in complete sets of equipment.

Mounting frames are used to support various components and are suitable for installation in complete sets of equipment.

Enclosure: The enclosure is a component that protects the equipment from certain external factors and prevents direct access to the equipment in all directions. Its protection level is at least IP30.

Door: A hinged or sliding cover plate.

Cover plate is the upper and lower shell surface of the enclosure, usually a component on the busbar trunking equipment, used to cover the openings on the enclosure. It is fixed with screws or similar methods and is generally not removed after the equipment is put into operation.

Side plate is the left and right shell surface of the enclosure, usually a component on the busbar trunking equipment, used to cover the openings on the enclosure. It is fixed with screws or similar methods and is generally not removed after the equipment is put into operation.

Insulating baffle is a component used to protect against direct contact from various directions at the entrance and from arcs from switching devices and similar devices.

Live parts are conductors or conductive parts that are energized during normal use, including neutral conductors, but excluding neutral protective conductors.

Exposed conductive parts are accessible conductive parts of electrical equipment that are usually not energized, but may be energized under fault conditions.

Protective conductor is a conductor that is electrically connected to the following parts to prevent electric shock hazards.

Special reminder: Cables are indicated by cross-sectional area, while busbar trunking is indicated by rated operating current (generally referred to as 400A busbar trunking). A 400A domestic product has a cross-sectional area of 240mm, while some only have 180mm.

Guangzhou Tianqin Electrical Equipment Co., Ltd. is located beside Shapu Lixin Highway in Xintang Town, Zengcheng District, Guangzhou City (opposite Zengcheng Guangben Factory). The company focuses on the R&D, production, sales, and installation of busbar trunking products and comprehensive services for busbar trunking power distribution systems, providing busbar trunking power distribution system products and engineering services to numerous enterprises. Welcome to inquire: 13926168592.